Resource Type

Journal Article 650

Conference Videos 12

Year

2024 2

2023 47

2022 48

2021 44

2020 42

2019 34

2018 27

2017 34

2016 20

2015 27

2014 14

2013 29

2012 38

2011 39

2010 36

2009 28

2008 36

2007 33

2006 17

2005 13

open ︾

Keywords

monitoring 16

dynamic 15

dynamic response 14

dynamic analysis 11

dynamic simulation 10

Machine learning 6

dynamic characteristics 6

numerical simulation 6

microseismic monitoring 5

structural health monitoring 4

Condition monitoring 3

dynamic model 3

fault diagnosis 3

simulation 3

Adaptive dynamic programming 2

Artificial intelligence 2

CO2 capture 2

Deep learning 2

Multi-agent system 2

open ︾

Search scope:

排序: Display mode:

Continuous dynamic monitoring of a centenary iron bridge for structural modification assessment

Carmelo GENTILE,Antonella SAISI

Frontiers of Structural and Civil Engineering 2015, Volume 9, Issue 1,   Pages 26-41 doi: 10.1007/s11709-014-0284-4

Abstract: A multi-channel continuous dynamic monitoring system has been installed in a centenary iron arch bridgeThe monitoring project follows a series of preliminary ambient vibration tests carried out on the bridgeThe paper describes the bridge structure and its dynamic characteristics identified from the experimentalstudies developed since 2009, the installed monitoring system and the software developed in LabVIEWpresented and discussed, highlighting the effects of environmental and operational conditions on the bridge dynamic

Keywords: automated modal identification     continuous dynamic monitoring     environmental/operational effects     iron archbridge     structural health monitoring    

Non-invasive continuous blood pressure monitoring: a review of current applications

Elena Chung, Guo Chen, Brenton Alexander, Maxime Cannesson

Frontiers of Medicine 2013, Volume 7, Issue 1,   Pages 91-101 doi: 10.1007/s11684-013-0239-5

Abstract:

Blood pressure monitoring has come a long way from the initial observations made by Reverend HalesThere are none that deny the importance of monitoring perioperative blood pressure; however, the limitedability of the current prevalent technology (oscillometric blood pressure monitoring) to offer continuousInvasive monitoring is able to detect beat-to-beat blood pressure measurement, but the risks inherent, and especially the creation of those offering non-invasive but continuous blood pressure monitoring

Keywords: non-invasive blood pressure monitoring     continuous blood pressure monitoring     invasive blood pressure monitoring    

Decreasing complexity of glucose time series derived from continuous glucose monitoring is correlated

Frontiers of Medicine 2023, Volume 17, Issue 1,   Pages 68-74 doi: 10.1007/s11684-022-0955-9

Abstract: new parameter for continuously evaluating personal clinical statuses, the newly developed technique “continuousglucose monitoring” (CGM) can characterize glucose dynamics.

Keywords: complexity of glucose time series     continuous glucose monitoring     impaired glucose regulation     insulin    

Anti-biofouling strategies for implantable biosensors of continuous glucose monitoring systems

Frontiers of Chemical Science and Engineering 2023, Volume 17, Issue 12,   Pages 1866-1878 doi: 10.1007/s11705-023-2340-x

Abstract: Continuous glucose monitoring (CGM) systems play an increasingly vital role in the glycemic control of

Keywords: implantable glucose biosensor     anti-biofouling     continuous glucose monitoring     immune responses    

Frontier of continuous structural health monitoring system for short & medium span bridges and condition

Ayaho MIYAMOTO, Risto KIVILUOMA, Akito YABE

Frontiers of Structural and Civil Engineering 2019, Volume 13, Issue 3,   Pages 569-604 doi: 10.1007/s11709-018-0498-y

Abstract: Bridge health monitoring using information technology and sensors is capable of providing more accurateThe aim of this paper is to introduce a state-of-the-art on not only a rational bridge health monitoringcommunication technologies for lifetime management of existing short and medium span bridges but also a continuousdata collecting system designed for bridge health monitoring of mainly short and medium span bridgessafety indices, namely, “characteristic deflection” which is relatively free from the influence of dynamic

Keywords: condition assessment     short & medium span bridge     structural health monitoring(SHM)     long-term data collection    

Special issue: Wind turbine dynamic modeling, condition monitoring and diagnosis

Zheng YOU, Jinji GAO, Fulei CHU, Tielin SHI

Frontiers of Mechanical Engineering 2017, Volume 12, Issue 3,   Pages 279-280 doi: 10.1007/s11465-017-0476-4

Distributed fiber optic monitoring of a CFA pile with a central reinforcement bar bundle

Yi RUI, Nicholas de BATTISTA, Cedric KECHAVARZI, Xiaomin XU, Mei YIN

Frontiers of Structural and Civil Engineering 2021, Volume 15, Issue 1,   Pages 167-176 doi: 10.1007/s11709-020-0581-z

Abstract: present an application of distributed fiber optic sensor (DFOS) technology to measure the strain of a continuous

Keywords: continuous flight auger pile     static load test     central reinforcement bar bundle     distributed fiber optic    

Low-carbohydrate diets lead to greater weight loss and better glucose homeostasis than exercise: a randomized clinical trial

Frontiers of Medicine 2021, Volume 15, Issue 3,   Pages 460-471 doi: 10.1007/s11684-021-0861-6

Abstract: Lifestyle interventions, including dietary adjustments and exercise, are important for obesity management. This study enrolled adults with overweight or obesity to explore whether either low-carbohydrate diet (LCD) or exercise is more effective in metabolism improvement. Forty-five eligible subjects were randomly divided into an LCD group (n=22) and an exercise group (EX, n=23). The subjects either adopted LCD (carbohydrate intake<50 g/day) or performed moderate-to-vigorous exercise (≥30 min/day) for 3 weeks. After the interventions, LCD led to a larger weight loss than EX (−3.56±0.37 kg vs. −1.24±0.39 kg, P<0.001), as well as a larger reduction in fat mass (−2.10±0.18 kg vs. −1.25±0.24 kg, P=0.007) and waist circumference (−5.25±0.52 cm vs. −3.45±0.38 cm, P=0.008). Both interventions reduced visceral and subcutaneous fat and improved liver steatosis and insulin resistance. Triglycerides decreased in both two groups, whereas low-density lipoprotein cholesterol increased in the LCD group but decreased in the EX group. Various glycemic parameters, including serum glycated albumin, mean sensor glucose, coefficient of variability (CV), and largest amplitude of glycemic excursions, substantially declined in the LCD group. Only CV slightly decreased after exercise. This pilot study suggested that the effects of LCD and exercise are similar in alleviating liver steatosis and insulin resistance. Compared with exercise, LCD might be more efficient for weight loss and glucose homeostasis in people with obesity.

Keywords: low-carbohydrate diet     obesity     nonalcoholic fatty liver disease     continuous glucose monitoring     mean    

An intelligent IEQ monitoring and feedback system: Development and applications Article

Yang Geng,Zhongchen Zhang,Juan Yu,Hongzhong Chen,Hao Zhou,Borong Lin,Weimin Zhuang

Engineering 2022, Volume 18, Issue 11,   Pages 218-231 doi: 10.1016/j.eng.2021.09.017

Abstract: Therefore, continuous IEQ monitoring and feedback is of great concern in both the industrial and academiccost-effectively promote IEQ measurement while ignoring interactions between the human side and IEQ monitoringIn this study, an intelligent IEQ monitoring and feedback system (IBEM) is developed.

Keywords: Indoor environmental quality (IEQ)     Sensors     Continuous monitoring     Graphical user interface     Interactive    

Strain and process engineering toward continuous industrial fermentation

Frontiers of Chemical Science and Engineering 2023, Volume 17, Issue 10,   Pages 1336-1353 doi: 10.1007/s11705-022-2284-6

Abstract: To increase the economic competitiveness of biological processes, continuous fermentation technologiesHowever, several key challenges should be addressed for the industrial application of continuous fermentation

Keywords: continuous fermentation     productivity     contamination     strain degeneration     metabolic engineering    

Ant colony optimization in continuous problem

YU Ling, LIU Kang, LI Kaishi

Frontiers of Mechanical Engineering 2007, Volume 2, Issue 4,   Pages 459-462 doi: 10.1007/s11465-007-0079-6

Abstract: Based on the analysis of the basic ant colony optimization and optimum problem in a continuous space,an ant colony optimization (ACO) for continuous problem is constructed and discussed.The algorithm is efficient and beneficial to the study of the ant colony optimization in a continuous

Keywords: beneficial     algorithm     efficient     continuous     ACO    

Industrialization of the Advanced Technology in Continuous Casting of Steel

Gan Yong

Strategic Study of CAE 2002, Volume 4, Issue 9,   Pages 12-18

Abstract:

The characteristics of key technology in high-effective and thin-slab continuous casting of steeltechnologies such as soft reduction, hydraulic-driven non-sinusoidal oscillation, and electromagnetic continuousThe progress direction of high-efficiency and high quality of conventional continuous casting is discussed, and the development trend of near-net-shape continuous casting and electromagnetic continuous casing

Keywords: continuous casting of steel     high-effective continuous casting     thin slab continuous casting     soft reduction     electromagnetic continuous casting     industrialization    

A thermally flexible and multi-site tactile sensor for remote 3D dynamic sensing imaging

Guoting Xia, Yinuo Huang, Fujiang Li, Licheng Wang, Jinbo Pang, Liwei Li, Kai Wang

Frontiers of Chemical Science and Engineering 2020, Volume 14, Issue 6,   Pages 1039-1051 doi: 10.1007/s11705-019-1901-5

Abstract: A flexible, multi-site tactile and thermal sensor (MTTS) based on polyvinylidene fluoride (resolution 50 × 50) is reported. It can be used to implement spatial mapping caused by tactile and thermal events and record the two-dimensional motion trajectory of a tracked target object. The output voltage and current signal are recorded as a mapping by sensing the external pressure and thermal radiation stimulus, and the response distribution is dynamically observed on the three-dimensional interface. Through the mapping relationship between the established piezoelectric and pyroelectric signals, the piezoelectric component and the pyroelectric component are effectively extracted from the composite signals. The MTTS has a good sensitivity for tactile and thermal detection, and the electrodes have good synchronism. In addition, the signal interference is less than 9.5% and decreases as the pressure decreases after the distance between adjacent sites exceeds 200 µm. The integration of MTTS and signal processing units has potential applications in human-machine interaction systems, health status detection and smart assistive devices.

Keywords: tactile/thermal sensor     piezoelectric/pyroelectric effects     high resolution     spatial mapping     motion monitoring    

Bending and rotational behaviour of semi-continuous composite beams

WANG Jingfeng, LI Guoqiang

Frontiers of Structural and Civil Engineering 2008, Volume 2, Issue 2,   Pages 116-122 doi: 10.1007/s11709-008-0015-9

Abstract: Stresses and deflections were measured in various semi-continuous composite beams.The tests show that the semi-continuous composite beams are more economic and effective than the simpleor continuous composite beams.

Keywords: rotational     effective     deflection calculation     semi-continuous composite     full-scale semi-rigid    

Seismic performance of fabricated continuous girder bridge with grouting sleeve-prestressed tendon composite

Frontiers of Structural and Civil Engineering   Pages 827-854 doi: 10.1007/s11709-023-0954-1

Abstract: A numerical analysis of three types of continuous girder bridges was conducted with different piers:

Keywords: seismic performance     continuous girder bridge     grouting sleeve-prestressed tendon composite connections    

Title Author Date Type Operation

Continuous dynamic monitoring of a centenary iron bridge for structural modification assessment

Carmelo GENTILE,Antonella SAISI

Journal Article

Non-invasive continuous blood pressure monitoring: a review of current applications

Elena Chung, Guo Chen, Brenton Alexander, Maxime Cannesson

Journal Article

Decreasing complexity of glucose time series derived from continuous glucose monitoring is correlated

Journal Article

Anti-biofouling strategies for implantable biosensors of continuous glucose monitoring systems

Journal Article

Frontier of continuous structural health monitoring system for short & medium span bridges and condition

Ayaho MIYAMOTO, Risto KIVILUOMA, Akito YABE

Journal Article

Special issue: Wind turbine dynamic modeling, condition monitoring and diagnosis

Zheng YOU, Jinji GAO, Fulei CHU, Tielin SHI

Journal Article

Distributed fiber optic monitoring of a CFA pile with a central reinforcement bar bundle

Yi RUI, Nicholas de BATTISTA, Cedric KECHAVARZI, Xiaomin XU, Mei YIN

Journal Article

Low-carbohydrate diets lead to greater weight loss and better glucose homeostasis than exercise: a randomized clinical trial

Journal Article

An intelligent IEQ monitoring and feedback system: Development and applications

Yang Geng,Zhongchen Zhang,Juan Yu,Hongzhong Chen,Hao Zhou,Borong Lin,Weimin Zhuang

Journal Article

Strain and process engineering toward continuous industrial fermentation

Journal Article

Ant colony optimization in continuous problem

YU Ling, LIU Kang, LI Kaishi

Journal Article

Industrialization of the Advanced Technology in Continuous Casting of Steel

Gan Yong

Journal Article

A thermally flexible and multi-site tactile sensor for remote 3D dynamic sensing imaging

Guoting Xia, Yinuo Huang, Fujiang Li, Licheng Wang, Jinbo Pang, Liwei Li, Kai Wang

Journal Article

Bending and rotational behaviour of semi-continuous composite beams

WANG Jingfeng, LI Guoqiang

Journal Article

Seismic performance of fabricated continuous girder bridge with grouting sleeve-prestressed tendon composite

Journal Article